Product Description
The medium voltage metal enclosed switchgear is developed for 24 kV distribution systems that require high current capacity, dependable fault interruption, and organized metal-clad construction. The KYN28-24/3150-31.5 model is configured for 24 kV rated voltage, 3150 A rated current, and 31.5 kA short-circuit breaking capacity. It can serve as incoming, feeder, bus-coupler, transformer, capacitor, metering, or station-service equipment within a coordinated switchgear lineup. Our medium voltage metal enclosed switchgear separates the circuit breaker, busbar, cable, and low-voltage control compartments to improve operating discipline and maintenance access. A withdrawable vacuum circuit breaker can be moved between service, test, and disconnected positions according to the design, while mechanical and electrical interlocks support the intended operating sequence. The cabinet is not treated as an isolated panel; the arrangement is reviewed as part of the complete substation, including incoming cable direction, busbar connection, protection coordination, control power, communication, room dimensions, and future extension requirements.

We manufacture medium voltage metal enclosed switchgear in a factory that combines enclosure processing, component assembly, wiring, testing, and after-sales support. With more than 40 years of operation, a 36,000-square-meter facility, and 128 employees, Jiangsu Guoxing Electric Equipment Co., Ltd. can manage both repeat production and project-specific engineering. CNC fabrication accuracy up to ±0.1 mm for applicable sheet-metal parts supports consistent section alignment and reliable movement of withdrawable equipment. The medium voltage metal enclosed switchgear can be customized with customer-specified circuit breakers, relays, instrument transformers, meters, arc-protection devices, communication gateways, and cable interfaces. Production is controlled by model-specific quality documents, and every finished cabinet receives 100% inspection before packing. The factory can provide inspection records, production photos or videos, and third-party inspection access when requirements are defined in advance. Standard products are normally scheduled in about five working days, while customized orders generally require seven to fifteen working days after technical approval. This disciplined but flexible process helps distributors and EPC contractors reduce technical risk while maintaining room for local-brand components, private labeling, and market-specific documentation.
Specifications
|
Parameter |
Specification |
|
Model / Series |
KYN28-24/3150-31.5 medium-voltage metal-enclosed switchgear |
|
Rated Voltage |
24 kV |
|
Rated Current |
3150 A |
|
Rated Short-Circuit Breaking Current |
31.5 kA |
|
Installation |
Indoor, floor-standing, sectional lineup |
|
Structure |
Metal-clad, compartmentalized, withdrawable vacuum circuit-breaker type |
|
Control Options |
Protection relay, metering, communication, remote control, and arc-detection options |
Applications
Utility and Industrial Substations
Primary distribution, feeder protection, and bus sectionalizing.
High-Load Manufacturing
Power supply for large motors, furnaces, production lines, and process equipment.
Renewable Energy Facilities
Collector and distribution systems for solar, wind, and energy-support projects.
Large Public Infrastructure
Distribution for airports, rail systems, hospitals, water plants, and major buildings.
Customization Capability
We can customize the panel lineup, circuit function, breaker and relay brands, CT/PT ratios, busbar arrangement, cable interface, control voltage, communication protocol, and enclosure color.
Technical drawings, prototypes, or customer specifications can be used as the production basis, and OEM/ODM branding is available for qualified projects.
Quality Control
The inspection process covers incoming components, cabinet fabrication, mechanical alignment, breaker operation, interlocks, earthing, busbar installation, secondary wiring, insulation, and functional simulation.
All products are fully inspected before packing. Test records and third-party inspection coordination are available when included in the order requirements.
After-Sales Service
A dedicated after-sales department manages service records and coordinates the quality, engineering, production, purchasing, and sales teams. Technical personnel can participate directly in diagnosis and service planning.
The standard warranty is 18 months from shipment. Spare parts, remote technical guidance, repair, replacement, and return coordination are provided according to the confirmed issue.
Hot Tags: medium voltage metal enclosed switchgear, China medium voltage metal enclosed switchgear manufacturers, factory, AC Metal enclosed Switchgear, Compact Unit Substation, High Voltage Electrical Control Equipment, High Voltage Power Safety Equipment, High Voltage Ring Main Unit, High Voltage Utility Distribution System