Product Overview

 

Circuit breakers interrupt fault currents and isolate downstream loads during overloads or short circuits. Modern industrial installations require fast fault clearing times, precise trip-curve customization, and high short-circuit withstand capabilities. Units utilize advanced arc-chute geometry and silver-alloy contact tips to suppress arcs rapidly, minimizing thermal stress on downstream distribution transformers and cables.

 

 
  • Miniature Magnetic Circuit Breaker

    For global switchgear manufacturers, electrical distributors, and industrial engineering companies, we provide OEM/ODM customization services for Miniature magnetic circuit breaker. Customers can

  • DC Vacuum Circuit Breaker

    For global high-voltage switchgear manufacturers, EPC contractors, and overseas power project suppliers, we provide OEM/ODM customization services for DC vacuum circuit breaker. Customers can

  • Intelligent Moulded Case Circuit Breaker

    For global switchgear manufacturers, electrical distributors, and engineering contractors, we provide full OEM/ODM customization services for Intelligent moulded case circuit breaker. Customers can

  • Indoor Load Isolation Switch

    For global switchgear manufacturers, electrical distributors, and engineering contractors, we provide complete OEM/ODM customization services for Indoor load isolation switch. Customers can customize

  • HD Series Isolating Knife Switch With Fuse

    As a source manufacturer with 42 years of experience in low voltage electrical components, we independently develop and mass-produce HD Series Isolating Knife Switch with Fuse, an integrated

  • Manual Circuit Breaker Operating Mechanism

    The Manual circuit breaker operating mechanism integrates multiple normally open and normally closed contacts, enabling real-time feedback of circuit breaker ON, OFF, and fault status signals. It can

  • Electrical Under Voltage Auxiliary Release

    The Electrical under voltage auxiliary release is available in AC220V and AC380V control voltage specifications. When the grid voltage drops below 70% of the rated voltage, it quickly triggers

  • Shunt Release

    For remote control and automated safety shutoffs in industrial electrical networks, the MX Shunt release coil is a critical component. Over our 42-year journey of manufacturing innovation since 1984,

  • Undervoltage Release

    To ensure complete electrical grid safety and prevent damage during voltage fluctuations, a reliable auxiliary component is indispensable. Our factory, with 42 years of electrical manufacturing

  • Intelligent Frame Circuit Breaker

    Designed specifically for sub-main distribution boards and industrial motor control centers, the Intelligent frame circuit breaker (specifically focusing on our compact series ranging from 200A to

  • Intelligent Air Circuit Breaker

    As smart grids and real-time digital monitoring become mandatory standards for modern power infrastructure, we have developed our high-end Intelligent air circuit breaker (spanning 630A to 3200A) to

  • Air Circuit Breaker

    In commercial, industrial, and marine low-voltage distribution grids, the main incoming breaker is the critical line of defense for the entire electrical network. Drawing from our 42 years of

First 123 Last
 
Types & Configurations
 

Type

Standard Current Range

Breaking Capacity (Icu)

Primary Application

Air Circuit Breakers (ACB)

630A – 6300A

50kA – 120kA

Main incoming switchboards, large industrial plants, transformer protection

Molded Case Circuit Breakers (MCCB)

16A – 1600A

25kA – 100kA

Sub-distribution boards, motor control centers (MCC), commercial buildings

Vacuum Circuit Breakers (VCB)

630A – 4000A (MV: 10kV–35kV)

20kA – 50kA

Medium-voltage primary distribution, renewable energy substations

 

Miniature Magnetic Circuit Breaker suppliers

 

Key Features

Microprocessor Trip Units: LCD-equipped digital controllers allow precise adjustments for long-time (Ir), short-time (Isd), instantaneous (Ii), and ground-fault (Ig) protection thresholds.


Contact Material: AgW (Silver-Tungsten) composite contact tips resist welding under high fault-current closure events.


Modular Internal Architecture: Shunt trips, auxiliary contacts, and undervoltage releases install via snap-in modular slots without requiring factory recalibration.


Mechanical Indication: Clear mechanical trip flags isolate visual status from auxiliary switch signaling to verify contact separation during maintenance.

 

Applications

 

Air Circuit Breaker manufacturers

Data Centers

Continuous uptime demands selective coordination between incoming ACBs and feeder MCCBs to isolate localized faults without tripping main feeds.

Air Circuit Breaker best

Renewable Energy

Photovoltaic and wind turbine inverter skids utilize DC-rated and high-ambient-temperature breakers rated up to 1000V DC / 1500V DC.

Air Circuit Breaker factory

Heavy Manufacturing

Steel mills and chemical processing plants require high short-time withstand current (Icw) ratings to handle motor starting surges and harsh, corrosive environments.

 

 

Manufacturing & Quality Control

Stamping & Molding: Copper busbars utilize high-conductivity electrolytic tough pitch (ETP) copper, CNC-stamped to dimensional tolerances within +/- 0.05 mm. Molded housings utilize flame-retardant BMC (Bulk Molding Compound) with a UL94 V-0 rating.


Calibration & Testing: Every assembled pole passes automated micro-ohm resistance testing across closed contacts to verify contact pressure and prevent localized hot spots.


Dielectric Testing: Units undergo 50Hz AC withstand voltage testing at 2.5kV for 1 minute across open contacts to verify insulation integrity.

Miniature Magnetic Circuit Breaker factory

 

Customization & Project Support

Busbar Adaptation

Custom terminal extensions and vertical/horizontal phase barrier configurations adapt to non-standard switchboard enclosures.

Communication Protocols

Integration of Modbus-RTU, PROFIBUS, or Ethernet communication modules enables remote telemetry of voltage, current, power factor, and harmonic distortion.

Engineering Data Packages

STEP files, time-current characteristic (TCC) curves, and seismic qualification reports deliver directly to engineering teams during the design phase.

 

Certifications & Quality Assurance
 

Compliance Standards

IEC 60947-2 (Low-voltage switchgear and controlgear - Circuit-breakers) and GB/T 14048.2.

Type Testing

Certified short-circuit breaking capacity validated by independent laboratories through witness testing procedures.

Traceability

Laser-engraved serial numbers link directly to raw material lot sheets, assembly operator logs, and routine test calibration records.

 

 

FAQ

 

Q: What is the difference between Ics and Icu, and which parameter should I prioritize for industrial panel design?

A: Icu (Ultimate Short-Circuit Breaking Capacity) is the maximum fault current the breaker can interrupt once without sustaining structural damage that prevents future operation. Ics (Service Short-Circuit Breaking Capacity) is expressed as a percentage of Icu and indicates the breaker's ability to continue operating normally after clearing a fault. Prioritize 100% Ics ratings for mission-critical applications where uninterrupted power continuity is mandatory.

Q: How do electronic trip units differ from thermal-magnetic units in selectivity?

A: Electronic trip units provide adjustable time-current curves with distinct thresholds for overload, short-circuit, and instantaneous trips. This digital adjustability allows engineers to configure precise time delays, ensuring that the upstream breaker remains closed while the downstream breaker closest to the fault opens. Thermal-magnetic units rely on fixed bi-metallic strips and magnetic coils, offering less granularity for complex cascade coordination.

Q: Can these circuit breakers operate in high-ambient-temperature environments without derating?

A: Standard circuit breakers are calibrated at an ambient temperature of 40 deg C. Operating environments exceeding 40 deg C require thermal current derating based on manufacturer-provided temperature correction curves. For installations in tropical or enclosed enclosures up to 55 deg C, specify heavy-duty internal components or select a frame size one tier higher to prevent nuisance tripping.

Q: What communication protocols are supported for remote monitoring and SCADA integration?

A: Standard electronic trip units integrate internal communication modules supporting Modbus-RTU over RS485 physical layers. Optional gateway modules convert data to PROFIBUS-DP, Modbus-TCP, or IEC 61850 protocols, enabling real-time transmission of phase currents, active power, energy consumption, and fault event logs directly to plant energy management systems.

Q: What is the typical lead time for custom busbar configurations and non-standard voltage coils?

A: Standard catalog items ship within 5 to 7 business days. Custom modifications—such as specific auxiliary contact configurations, specialized shunt release voltages, or extended terminal lugs—typically require 15 to 20 business days following engineering drawing sign-off.

Q: What documentation is provided to satisfy third-party panel inspection requirements?

A: Each shipment includes individual routine test reports detailing calibration, mechanical operation checks, and dielectric withstand results. Type test certificates, declarations of conformity, RoHS compliance statements, and 3D CAD files issue digitally prior to freight dispatch.

As one of the most professional circuit breaker manufacturers in China, we're featured by quality products and low price. Please rest assured to buy discount circuit breaker made in China here from our factory. Customized orders are welcome.

Send Inquiry